From 7084f8429c940bac856123ce6d3946638fe20364 Mon Sep 17 00:00:00 2001 From: Roland Dreier Date: Fri, 16 Feb 2007 15:31:24 -0800 Subject: [PATCH] IB/core: Set static rate in ib_init_ah_from_path() The static rate from the path record should be put into the address vector -- a long time ago the rate in the address attributes needed to be a relative rate, which required more munging, but now that the conversion from absolute to relative is done in the low-level driver, it's easy for ib_init_ah_from_path() to put the absolute rate in. Cc: Jason Gunthorpe Cc: Sean Hefty Signed-off-by: Roland Dreier --- drivers/infiniband/core/sa_query.c | 1 + 1 file changed, 1 insertion(+) diff --git a/drivers/infiniband/core/sa_query.c b/drivers/infiniband/core/sa_query.c index d7d4a5309b..68db633711 100644 --- a/drivers/infiniband/core/sa_query.c +++ b/drivers/infiniband/core/sa_query.c @@ -471,6 +471,7 @@ int ib_init_ah_from_path(struct ib_device *device, u8 port_num, ah_attr->sl = rec->sl; ah_attr->src_path_bits = be16_to_cpu(rec->slid) & 0x7f; ah_attr->port_num = port_num; + ah_attr->static_rate = rec->rate; if (rec->hop_limit > 1) { ah_attr->ah_flags = IB_AH_GRH; -- 2.39.5