From 6ca2cdcc5e40286e6bf5286056b50a56c8ce327e Mon Sep 17 00:00:00 2001 From: Takashi Iwai Date: Fri, 10 Aug 2007 17:22:34 +0200 Subject: [PATCH] [ALSA] hda-codec - update of documentation Update the documentation to reflect the last changes regarding the power-saving mode and register caches. Signed-off-by: Takashi Iwai Signed-off-by: Jaroslav Kysela --- Documentation/sound/alsa/hda_codec.txt | 49 +++++++++++++++++++------- 1 file changed, 36 insertions(+), 13 deletions(-) diff --git a/Documentation/sound/alsa/hda_codec.txt b/Documentation/sound/alsa/hda_codec.txt index 4eaae2a455..8e1b025266 100644 --- a/Documentation/sound/alsa/hda_codec.txt +++ b/Documentation/sound/alsa/hda_codec.txt @@ -49,6 +49,9 @@ struct hda_bus_ops { unsigned int verb, unsigned int parm); unsigned int (*get_response)(struct hda_codec *codec); void (*private_free)(struct hda_bus *); +#ifdef CONFIG_SND_HDA_POWER_SAVE + void (*pm_notify)(struct hda_codec *codec); +#endif }; The command callback is called when the codec module needs to send a @@ -56,9 +59,16 @@ VERB to the controller. It's always a single command. The get_response callback is called when the codec requires the answer for the last command. These two callbacks are mandatory and have to be given. -The last, private_free callback, is optional. It's called in the +The third, private_free callback, is optional. It's called in the destructor to release any necessary data in the lowlevel driver. +The pm_notify callback is available only with +CONFIG_SND_HDA_POWER_SAVE kconfig. It's called when the codec needs +to power up or may power down. The controller should check the all +belonging codecs on the bus whether they are actually powered off +(check codec->power_on), and optionally the driver may power down the +contoller side, too. + The bus instance is created via snd_hda_bus_new(). You need to pass the card instance, the template, and the pointer to store the resultant bus instance. @@ -86,10 +96,8 @@ resultant codec instance (can be NULL if not needed). The codec is stored in a linked list of bus instance. You can follow the codec list like: - struct list_head *p; struct hda_codec *codec; - list_for_each(p, &bus->codec_list) { - codec = list_entry(p, struct hda_codec, list); + list_for_each_entry(codec, &bus->codec_list, list) { ... } @@ -100,10 +108,15 @@ initialization sequence is called when the controls are built later. Codec Access ============ -To access codec, use snd_codec_read() and snd_codec_write(). +To access codec, use snd_hda_codec_read() and snd_hda_codec_write(). snd_hda_param_read() is for reading parameters. For writing a sequence of verbs, use snd_hda_sequence_write(). +There are variants of cached read/write, snd_hda_codec_write_cache(), +snd_hda_sequence_write_cache(). These are used for recording the +register states for the power-mangement resume. When no PM is needed, +these are equivalent with non-cached version. + To retrieve the number of sub nodes connected to the given node, use snd_hda_get_sub_nodes(). The connection list can be obtained via snd_hda_get_connections() call. @@ -239,6 +252,10 @@ set the codec->patch_ops field. This is defined as below: int (*suspend)(struct hda_codec *codec, pm_message_t state); int (*resume)(struct hda_codec *codec); #endif + #ifdef CONFIG_SND_HDA_POWER_SAVE + int (*check_power_status)(struct hda_codec *codec, + hda_nid_t nid); + #endif }; The build_controls callback is called from snd_hda_build_controls(). @@ -251,6 +268,18 @@ The unsol_event callback is called when an unsolicited event is received. The suspend and resume callbacks are for power management. +They can be NULL if no special sequence is required. When the resume +callback is NULL, the driver calls the init callback and resumes the +registers from the cache. If other handling is needed, you'd need to +write your own resume callback. There, the amp values can be resumed +via + void snd_hda_codec_resume_amp(struct hda_codec *codec); +and the other codec registers via + void snd_hda_codec_resume_cache(struct hda_codec *codec); + +The check_power_status callback is called when the amp value of the +given widget NID is changed. The codec code can turn on/off the power +appropriately from this information. Each entry can be NULL if not necessary to be called. @@ -267,8 +296,7 @@ Digital I/O =========== Call snd_hda_create_spdif_out_ctls() from the patch to create controls -related with SPDIF out. In the patch resume callback, call -snd_hda_resume_spdif(). +related with SPDIF out. Helper Functions @@ -284,12 +312,7 @@ as a module parameter, and PCI subsystem IDs. If the matching entry is found, it returns the config field value. snd_hda_add_new_ctls() can be used to create and add control entries. -Pass the zero-terminated array of struct snd_kcontrol_new. The same array -can be passed to snd_hda_resume_ctls() for resume. -Note that this will call control->put callback of these entries. So, -put callback should check codec->in_resume and force to restore the -given value if it's non-zero even if the value is identical with the -cached value. +Pass the zero-terminated array of struct snd_kcontrol_new Macros HDA_CODEC_VOLUME(), HDA_CODEC_MUTE() and their variables can be used for the entry of struct snd_kcontrol_new. -- 2.39.5