* enum cmb_format - types of supported measurement block formats
*
* @CMF_BASIC: traditional channel measurement blocks supported
- * by all machines that we run on
+ * by all machines that we run on
* @CMF_EXTENDED: improved format that was introduced with the z990
- * machine
- * @CMF_AUTODETECT: default: use extended format when running on a z990
- * or later machine, otherwise fall back to basic format
- **/
+ * machine
+ * @CMF_AUTODETECT: default: use extended format when running on a machine
+ * supporting extended format, otherwise fall back to
+ * basic format
+ */
enum cmb_format {
CMF_BASIC,
CMF_EXTENDED,
CMF_AUTODETECT = -1,
};
-/**
+/*
* format - actual format for all measurement blocks
*
* The format module parameter can be set to a value of 0 (zero)
* either with the help of a special pool or with kmalloc
* @free: free memory allocated with @alloc
* @set: enable or disable measurement
+ * @read: read a measurement entry at an index
* @readall: read a measurement block in a common format
* @reset: clear the data in the associated measurement block and
* reset its time stamp
int (*readall)(struct ccw_device *, struct cmbdata *);
void (*reset) (struct ccw_device *);
void *(*align) (void *);
-
+/* private: */
struct attribute_group *attr_group;
};
static struct cmb_operations *cmbops;
*
* @mem: pointer to CMBs (only in basic measurement mode)
* @list: contains a linked list of all subchannels
+ * @num_channels: number of channels to be measured
* @lock: protect concurrent access to @mem and @list
*/
struct cmb_area {
/**
* struct cmb - basic channel measurement block
+ * @ssch_rsch_count: number of ssch and rsch
+ * @sample_count: number of samples
+ * @device_connect_time: time of device connect
+ * @function_pending_time: time of function pending
+ * @device_disconnect_time: time of device disconnect
+ * @control_unit_queuing_time: time of control unit queuing
+ * @device_active_only_time: time of device active only
+ * @reserved: unused in basic measurement mode
+ *
+ * The measurement block as used by the hardware. The fields are described
+ * further in z/Architecture Principles of Operation, chapter 17.
*
- * cmb as used by the hardware the fields are described in z/Architecture
- * Principles of Operation, chapter 17.
- * The area to be a contiguous array and may not be reallocated or freed.
+ * The cmb area made up from these blocks must be a contiguous array and may
+ * not be reallocated or freed.
* Only one cmb area can be present in the system.
*/
struct cmb {
/**
* struct cmbe - extended channel measurement block
+ * @ssch_rsch_count: number of ssch and rsch
+ * @sample_count: number of samples
+ * @device_connect_time: time of device connect
+ * @function_pending_time: time of function pending
+ * @device_disconnect_time: time of device disconnect
+ * @control_unit_queuing_time: time of control unit queuing
+ * @device_active_only_time: time of device active only
+ * @device_busy_time: time of device busy
+ * @initial_command_response_time: initial command response time
+ * @reserved: unused
*
- * cmb as used by the hardware, may be in any 64 bit physical location,
- * the fields are described in z/Architecture Principles of Operation,
+ * The measurement block as used by the hardware. May be in any 64 bit physical
+ * location.
+ * The fields are described further in z/Architecture Principles of Operation,
* third edition, chapter 17.
*/
struct cmbe {
DEVICE_ATTR(cmb_enable, 0644, cmb_enable_show, cmb_enable_store);
-/* enable_cmf/disable_cmf: module interface for cmf (de)activation */
+/**
+ * enable_cmf() - switch on the channel measurement for a specific device
+ * @cdev: The ccw device to be enabled
+ *
+ * Returns %0 for success or a negative error value.
+ *
+ * Context:
+ * non-atomic
+ */
int enable_cmf(struct ccw_device *cdev)
{
int ret;
return ret;
}
+/**
+ * disable_cmf() - switch off the channel measurement for a specific device
+ * @cdev: The ccw device to be disabled
+ *
+ * Returns %0 for success or a negative error value.
+ *
+ * Context:
+ * non-atomic
+ */
int disable_cmf(struct ccw_device *cdev)
{
int ret;
return ret;
}
+/**
+ * cmf_read() - read one value from the current channel measurement block
+ * @cdev: the channel to be read
+ * @index: the index of the value to be read
+ *
+ * Returns the value read or %0 if the value cannot be read.
+ *
+ * Context:
+ * any
+ */
u64 cmf_read(struct ccw_device *cdev, int index)
{
return cmbops->read(cdev, index);
}
+/**
+ * cmf_readall() - read the current channel measurement block
+ * @cdev: the channel to be read
+ * @data: a pointer to a data block that will be filled
+ *
+ * Returns %0 on success, a negative error value otherwise.
+ *
+ * Context:
+ * any
+ */
int cmf_readall(struct ccw_device *cdev, struct cmbdata *data)
{
return cmbops->readall(cdev, data);
#ifndef S390_CMB_H
#define S390_CMB_H
/**
- * struct cmbdata -- channel measurement block data for user space
+ * struct cmbdata - channel measurement block data for user space
+ * @size: size of the stored data
+ * @elapsed_time: time since last sampling
+ * @ssch_rsch_count: number of ssch and rsch
+ * @sample_count: number of samples
+ * @device_connect_time: time of device connect
+ * @function_pending_time: time of function pending
+ * @device_disconnect_time: time of device disconnect
+ * @control_unit_queuing_time: time of control unit queuing
+ * @device_active_only_time: time of device active only
+ * @device_busy_time: time of device busy (ext. format)
+ * @initial_command_response_time: initial command response time (ext. format)
*
- * @size: size of the stored data
- * @ssch_rsch_count: XXX
- * @sample_count:
- * @device_connect_time:
- * @function_pending_time:
- * @device_disconnect_time:
- * @control_unit_queuing_time:
- * @device_active_only_time:
- * @device_busy_time:
- * @initial_command_response_time:
- *
- * all values are stored as 64 bit for simplicity, especially
+ * All values are stored as 64 bit for simplicity, especially
* in 32 bit emulation mode. All time values are normalized to
* nanoseconds.
* Currently, two formats are known, which differ by the size of
* this structure, i.e. the last two members are only set when
* the extended channel measurement facility (first shipped in
* z990 machines) is activated.
- * Potentially, more fields could be added, which results in a
+ * Potentially, more fields could be added, which would result in a
* new ioctl number.
- **/
+ */
struct cmbdata {
__u64 size;
__u64 elapsed_time;
#ifdef __KERNEL__
struct ccw_device;
-/**
- * enable_cmf() - switch on the channel measurement for a specific device
- * @cdev: The ccw device to be enabled
- * returns 0 for success or a negative error value.
- *
- * Context:
- * non-atomic
- **/
extern int enable_cmf(struct ccw_device *cdev);
-
-/**
- * disable_cmf() - switch off the channel measurement for a specific device
- * @cdev: The ccw device to be disabled
- * returns 0 for success or a negative error value.
- *
- * Context:
- * non-atomic
- **/
extern int disable_cmf(struct ccw_device *cdev);
-
-/**
- * cmf_read() - read one value from the current channel measurement block
- * @cmf: the channel to be read
- * @index: the name of the value that is read
- *
- * Context:
- * any
- **/
-
extern u64 cmf_read(struct ccw_device *cdev, int index);
-/**
- * cmf_readall() - read one value from the current channel measurement block
- * @cmf: the channel to be read
- * @data: a pointer to a data block that will be filled
- *
- * Context:
- * any
- **/
extern int cmf_readall(struct ccw_device *cdev, struct cmbdata *data);
#endif /* __KERNEL__ */