]> err.no Git - linux-2.6/commitdiff
power_supply: cleanup of the OLPC battery driver
authorAndres Salomon <dilinger@queued.net>
Fri, 2 May 2008 20:41:59 +0000 (13:41 -0700)
committerAnton Vorontsov <cbouatmailru@gmail.com>
Sun, 4 May 2008 09:14:05 +0000 (13:14 +0400)
Move portions of the massive switch statement into functions.  The layout of
this thing has already caused one bug (a break in the wrong place), it needed
to shrink.

Signed-off-by: Andres Salomon <dilinger@debian.org>
Cc: David Woodhouse <dwmw2@infradead.org>
Signed-off-by: Andrew Morton <akpm@linux-foundation.org>
Signed-off-by: Anton Vorontsov <cbouatmailru@gmail.com>
drivers/power/olpc_battery.c

index f8dc2b18bb49d8f5ed4ff49b5fa899592eb90533..d5fe6f0c9de0877e0cbef6477ddabda342d2eca1 100644 (file)
@@ -86,6 +86,117 @@ static struct power_supply olpc_ac = {
 
 static char bat_serial[17]; /* Ick */
 
+static int olpc_bat_get_status(union power_supply_propval *val, uint8_t ec_byte)
+{
+       if (olpc_platform_info.ecver > 0x44) {
+               if (ec_byte & BAT_STAT_CHARGING)
+                       val->intval = POWER_SUPPLY_STATUS_CHARGING;
+               else if (ec_byte & BAT_STAT_DISCHARGING)
+                       val->intval = POWER_SUPPLY_STATUS_DISCHARGING;
+               else if (ec_byte & BAT_STAT_FULL)
+                       val->intval = POWER_SUPPLY_STATUS_FULL;
+               else /* er,... */
+                       val->intval = POWER_SUPPLY_STATUS_NOT_CHARGING;
+       } else {
+               /* Older EC didn't report charge/discharge bits */
+               if (!(ec_byte & BAT_STAT_AC)) /* No AC means discharging */
+                       val->intval = POWER_SUPPLY_STATUS_DISCHARGING;
+               else if (ec_byte & BAT_STAT_FULL)
+                       val->intval = POWER_SUPPLY_STATUS_FULL;
+               else /* Not _necessarily_ true but EC doesn't tell all yet */
+                       val->intval = POWER_SUPPLY_STATUS_CHARGING;
+       }
+
+       return 0;
+}
+
+static int olpc_bat_get_health(union power_supply_propval *val)
+{
+       uint8_t ec_byte;
+       int ret;
+
+       ret = olpc_ec_cmd(EC_BAT_ERRCODE, NULL, 0, &ec_byte, 1);
+       if (ret)
+               return ret;
+
+       switch (ec_byte) {
+       case 0:
+               val->intval = POWER_SUPPLY_HEALTH_GOOD;
+               break;
+
+       case BAT_ERR_OVERTEMP:
+               val->intval = POWER_SUPPLY_HEALTH_OVERHEAT;
+               break;
+
+       case BAT_ERR_OVERVOLTAGE:
+               val->intval = POWER_SUPPLY_HEALTH_OVERVOLTAGE;
+               break;
+
+       case BAT_ERR_INFOFAIL:
+       case BAT_ERR_OUT_OF_CONTROL:
+       case BAT_ERR_ID_FAIL:
+       case BAT_ERR_ACR_FAIL:
+               val->intval = POWER_SUPPLY_HEALTH_UNSPEC_FAILURE;
+               break;
+
+       default:
+               /* Eep. We don't know this failure code */
+               ret = -EIO;
+       }
+
+       return ret;
+}
+
+static int olpc_bat_get_mfr(union power_supply_propval *val)
+{
+       uint8_t ec_byte;
+       int ret;
+
+       ec_byte = BAT_ADDR_MFR_TYPE;
+       ret = olpc_ec_cmd(EC_BAT_EEPROM, &ec_byte, 1, &ec_byte, 1);
+       if (ret)
+               return ret;
+
+       switch (ec_byte >> 4) {
+       case 1:
+               val->strval = "Gold Peak";
+               break;
+       case 2:
+               val->strval = "BYD";
+               break;
+       default:
+               val->strval = "Unknown";
+               break;
+       }
+
+       return ret;
+}
+
+static int olpc_bat_get_tech(union power_supply_propval *val)
+{
+       uint8_t ec_byte;
+       int ret;
+
+       ec_byte = BAT_ADDR_MFR_TYPE;
+       ret = olpc_ec_cmd(EC_BAT_EEPROM, &ec_byte, 1, &ec_byte, 1);
+       if (ret)
+               return ret;
+
+       switch (ec_byte & 0xf) {
+       case 1:
+               val->intval = POWER_SUPPLY_TECHNOLOGY_NiMH;
+               break;
+       case 2:
+               val->intval = POWER_SUPPLY_TECHNOLOGY_LiFe;
+               break;
+       default:
+               val->intval = POWER_SUPPLY_TECHNOLOGY_UNKNOWN;
+               break;
+       }
+
+       return ret;
+}
+
 /*********************************************************************
  *             Battery properties
  *********************************************************************/
@@ -113,25 +224,10 @@ static int olpc_bat_get_property(struct power_supply *psy,
 
        switch (psp) {
        case POWER_SUPPLY_PROP_STATUS:
-               if (olpc_platform_info.ecver > 0x44) {
-                       if (ec_byte & BAT_STAT_CHARGING)
-                               val->intval = POWER_SUPPLY_STATUS_CHARGING;
-                       else if (ec_byte & BAT_STAT_DISCHARGING)
-                               val->intval = POWER_SUPPLY_STATUS_DISCHARGING;
-                       else if (ec_byte & BAT_STAT_FULL)
-                               val->intval = POWER_SUPPLY_STATUS_FULL;
-                       else /* er,... */
-                               val->intval = POWER_SUPPLY_STATUS_NOT_CHARGING;
-               } else {
-                       /* Older EC didn't report charge/discharge bits */
-                       if (!(ec_byte & BAT_STAT_AC)) /* No AC means discharging */
-                               val->intval = POWER_SUPPLY_STATUS_DISCHARGING;
-                       else if (ec_byte & BAT_STAT_FULL)
-                               val->intval = POWER_SUPPLY_STATUS_FULL;
-                       else /* Not _necessarily_ true but EC doesn't tell all yet */
-                               val->intval = POWER_SUPPLY_STATUS_CHARGING;
-                       break;
-               }
+               ret = olpc_bat_get_status(val, ec_byte);
+               if (ret)
+                       return ret;
+               break;
        case POWER_SUPPLY_PROP_PRESENT:
                val->intval = !!(ec_byte & BAT_STAT_PRESENT);
                break;
@@ -140,72 +236,21 @@ static int olpc_bat_get_property(struct power_supply *psy,
                if (ec_byte & BAT_STAT_DESTROY)
                        val->intval = POWER_SUPPLY_HEALTH_DEAD;
                else {
-                       ret = olpc_ec_cmd(EC_BAT_ERRCODE, NULL, 0, &ec_byte, 1);
+                       ret = olpc_bat_get_health(val);
                        if (ret)
                                return ret;
-
-                       switch (ec_byte) {
-                       case 0:
-                               val->intval = POWER_SUPPLY_HEALTH_GOOD;
-                               break;
-
-                       case BAT_ERR_OVERTEMP:
-                               val->intval = POWER_SUPPLY_HEALTH_OVERHEAT;
-                               break;
-
-                       case BAT_ERR_OVERVOLTAGE:
-                               val->intval = POWER_SUPPLY_HEALTH_OVERVOLTAGE;
-                               break;
-
-                       case BAT_ERR_INFOFAIL:
-                       case BAT_ERR_OUT_OF_CONTROL:
-                       case BAT_ERR_ID_FAIL:
-                       case BAT_ERR_ACR_FAIL:
-                               val->intval = POWER_SUPPLY_HEALTH_UNSPEC_FAILURE;
-                               break;
-
-                       default:
-                               /* Eep. We don't know this failure code */
-                               return -EIO;
-                       }
                }
                break;
 
        case POWER_SUPPLY_PROP_MANUFACTURER:
-               ec_byte = BAT_ADDR_MFR_TYPE;
-               ret = olpc_ec_cmd(EC_BAT_EEPROM, &ec_byte, 1, &ec_byte, 1);
+               ret = olpc_bat_get_mfr(val);
                if (ret)
                        return ret;
-
-               switch (ec_byte >> 4) {
-               case 1:
-                       val->strval = "Gold Peak";
-                       break;
-               case 2:
-                       val->strval = "BYD";
-                       break;
-               default:
-                       val->strval = "Unknown";
-                       break;
-               }
                break;
        case POWER_SUPPLY_PROP_TECHNOLOGY:
-               ec_byte = BAT_ADDR_MFR_TYPE;
-               ret = olpc_ec_cmd(EC_BAT_EEPROM, &ec_byte, 1, &ec_byte, 1);
+               ret = olpc_bat_get_tech(val);
                if (ret)
                        return ret;
-
-               switch (ec_byte & 0xf) {
-               case 1:
-                       val->intval = POWER_SUPPLY_TECHNOLOGY_NiMH;
-                       break;
-               case 2:
-                       val->intval = POWER_SUPPLY_TECHNOLOGY_LiFe;
-                       break;
-               default:
-                       val->intval = POWER_SUPPLY_TECHNOLOGY_UNKNOWN;
-                       break;
-               }
                break;
        case POWER_SUPPLY_PROP_VOLTAGE_AVG:
                ret = olpc_ec_cmd(EC_BAT_VOLTAGE, NULL, 0, (void *)&ec_word, 2);