e1000_reset_adaptive(&adapter->hw);
e1000_phy_get_info(&adapter->hw, &adapter->phy_info);
+
+ if (!adapter->smart_power_down &&
+ (adapter->hw.mac_type == e1000_82571 ||
+ adapter->hw.mac_type == e1000_82572)) {
+ uint16_t phy_data = 0;
+ /* speed up time to link by disabling smart power down, ignore
+ * the return value of this function because there is nothing
+ * different we would do if it failed */
+ e1000_read_phy_reg(&adapter->hw, IGP02E1000_PHY_POWER_MGMT,
+ &phy_data);
+ phy_data &= ~IGP02E1000_PM_SPD;
+ e1000_write_phy_reg(&adapter->hw, IGP02E1000_PHY_POWER_MGMT,
+ phy_data);
+ }
+
if (adapter->en_mng_pt) {
manc = E1000_READ_REG(&adapter->hw, MANC);
manc |= (E1000_MANC_ARP_EN | E1000_MANC_EN_MNG2HOST);
E1000_PARAM(InterruptThrottleRate, "Interrupt Throttling Rate");
+/* Enable Smart Power Down of the PHY
+ *
+ * Valid Range: 0, 1
+ *
+ * Default Value: 0 (disabled)
+ */
+
+E1000_PARAM(SmartPowerDownEnable, "Enable PHY smart power down");
+
#define AUTONEG_ADV_DEFAULT 0x2F
#define AUTONEG_ADV_MASK 0x2F
#define FLOW_CONTROL_DEFAULT FLOW_CONTROL_FULL
adapter->itr = opt.def;
}
}
+ { /* Smart Power Down */
+ struct e1000_option opt = {
+ .type = enable_option,
+ .name = "PHY Smart Power Down",
+ .err = "defaulting to Disabled",
+ .def = OPTION_DISABLED
+ };
+
+ if (num_SmartPowerDownEnable > bd) {
+ int spd = SmartPowerDownEnable[bd];
+ e1000_validate_option(&spd, &opt, adapter);
+ adapter->smart_power_down = spd;
+ } else {
+ adapter->smart_power_down = opt.def;
+ }
+ }
switch (adapter->hw.media_type) {
case e1000_media_type_fiber: