]> err.no Git - linux-2.6/commitdiff
ACPI: ibm-acpi: Implement direct-ec-access thermal reading modes for up to 16 sensors
authorHenrique de Moraes Holschuh <hmh@hmh.eng.br>
Fri, 24 Nov 2006 13:47:08 +0000 (11:47 -0200)
committerLen Brown <len.brown@intel.com>
Thu, 7 Dec 2006 06:38:38 +0000 (01:38 -0500)
This patch extends ibm-acpi to support reading thermal sensors directly
through ACPI EC register access.  It uses a DMI match to detect ThinkPads
with a new-style embedded controller, that are known to have forward-
compatible register maps and use 0x00 to fill in non-used registers and
export thermal sensors at EC offsets 0x78-7F and 0xC0-C7.

Direct ACPI EC register access is implemented for 8-sensor and 16-sensor
new-style ThinkPad controller firmwares as an experimental feature.  The
code does some limited sanity checks on the temperatures read through EC
access, and will default to the old ACPI TMP0-7 mode if anything is amiss.

Userspace ABI is not changed for 8 sensors, but /proc/acpi/ibm/thermal is
extended for 16 sensors if the firmware supports 16 sensors.

A documentation update is also provided.

The information about the ThinkPad register map was determined by studying
ibm-acpi "ecdump" output from various ThinkPad models, submitted by
subscribers of the linux-thinkpad mailinglist.  Futher information was
gathered from the DSDT tables, as they describe the EC register map in
recent ThinkPads.

DSDT source shows that TMP0-7 access and direct register access are
actually the same thing on these firmwares, but unfortunately IBM never
did update their DSDT EC register map to export TMP8-TMP15 for the second
range of sensors.

Signed-off-by: Henrique de Moraes Holschuh <hmh@hmh.eng.br>
Documentation/ibm-acpi.txt
drivers/acpi/ibm_acpi.c

index e50595bfd8ea63e0cfc15c0c4cadd94e01ea1224..30f09e7a423e9ed8447b33e24492a69adbbcf0f2 100644 (file)
@@ -398,25 +398,56 @@ Temperature sensors -- /proc/acpi/ibm/thermal
 
 Most ThinkPads include six or more separate temperature sensors but
 only expose the CPU temperature through the standard ACPI methods.
-This feature shows readings from up to eight different sensors. Some
-readings may not be valid, e.g. may show large negative values. For
-example, on the X40, a typical output may be:
+This feature shows readings from up to eight different sensors on older
+ThinkPads, and it has experimental support for up to sixteen different
+sensors on newer ThinkPads.  Readings from sensors that are not available
+return -128.
 
+No commands can be written to this file.
+
+EXPERIMENTAL: The 16-sensors feature is marked EXPERIMENTAL because the
+implementation directly accesses hardware registers and may not work as
+expected. USE WITH CAUTION! To use this feature, you need to supply the
+experimental=1 parameter when loading the module.  When EXPERIMENTAL
+mode is enabled, reading the first 8 sensors on newer ThinkPads will
+also use an new experimental thermal sensor access mode.
+
+For example, on the X40, a typical output may be:
 temperatures:   42 42 45 41 36 -128 33 -128
 
-Thomas Gruber took his R51 apart and traced all six active sensors in
-his laptop (the location of sensors may vary on other models):
+EXPERIMENTAL: On the T43/p, a typical output may be:
+temperatures:   48 48 36 52 38 -128 31 -128 48 52 48 -128 -128 -128 -128 -128
+
+The mapping of thermal sensors to physical locations varies depending on
+system-board model (and thus, on ThinkPad model).
+
+http://thinkwiki.org/wiki/Thermal_Sensors is a public wiki page that
+tries to track down these locations for various models.
+
+Most (newer?) models seem to follow this pattern:
 
 1:  CPU
-2:  Mini PCI Module
-3:  HDD
+2:  (depends on model)
+3:  (depends on model)
 4:  GPU
-5:  Battery
-6:  N/A
-7:  Battery
-8:  N/A
+5:  Main battery: main sensor
+6:  Bay battery: main sensor
+7:  Main battery: secondary sensor
+8:  Bay battery: secondary sensor
+9-15: (depends on model)
+
+For the R51 (source: Thomas Gruber):
+2:  Mini-PCI
+3:  Internal HDD
+
+For the T43, T43/p (source: Shmidoax/Thinkwiki.org)
+http://thinkwiki.org/wiki/Thermal_Sensors#ThinkPad_T43.2C_T43p
+2:  System board, left side (near PCMCIA slot), reported as HDAPS temp
+3:  PCMCIA slot
+9:  MCH (northbridge) to DRAM Bus
+10: ICH (southbridge), under Mini-PCI card, under touchpad
+11: Power regulator, underside of system board, below F2 key
 
-No commands can be written to this file.
 
 EXPERIMENTAL: Embedded controller register dump -- /proc/acpi/ibm/ecdump
 ------------------------------------------------------------------------
index baf9492f0a79859691f85d94b9e84bb9c0a56cd9..1703c617c0e855df92ce5ece238204f66c1c4d33 100644 (file)
@@ -80,6 +80,7 @@
 #include <linux/proc_fs.h>
 #include <linux/backlight.h>
 #include <asm/uaccess.h>
+#include <linux/dmi.h>
 
 #include <acpi/acpi_drivers.h>
 #include <acpi/acnamesp.h>
@@ -221,13 +222,17 @@ enum thermal_access_mode {
        IBMACPI_THERMAL_NONE = 0,       /* No thermal support */
        IBMACPI_THERMAL_ACPI_TMP07,     /* Use ACPI TMP0-7 */
        IBMACPI_THERMAL_ACPI_UPDT,      /* Use ACPI TMP0-7 with UPDT */
+       IBMACPI_THERMAL_TPEC_8,         /* Use ACPI EC regs, 8 sensors */
+       IBMACPI_THERMAL_TPEC_16,        /* Use ACPI EC regs, 16 sensors */
 };
 
-#define IBMACPI_MAX_THERMAL_SENSORS  /* Max thermal sensors supported */
+#define IBMACPI_MAX_THERMAL_SENSORS 16 /* Max thermal sensors supported */
 struct ibm_thermal_sensors_struct {
        s32 temp[IBMACPI_MAX_THERMAL_SENSORS];
 };
 
+static int ibm_thinkpad_ec_found;
+
 struct ibm_struct {
        char *name;
        char param[32];
@@ -1290,7 +1295,52 @@ static enum thermal_access_mode thermal_read_mode;
 
 static int thermal_init(void)
 {
-       if (acpi_evalf(ec_handle, NULL, "TMP7", "qv")) {
+       u8 t, ta1, ta2;
+       int i;
+       int acpi_tmp7 = acpi_evalf(ec_handle, NULL, "TMP7", "qv");
+
+       if (ibm_thinkpad_ec_found && experimental) {
+               /*
+                * Direct EC access mode: sensors at registers
+                * 0x78-0x7F, 0xC0-0xC7.  Registers return 0x00 for
+                * non-implemented, thermal sensors return 0x80 when
+                * not available
+                */
+
+               ta1 = ta2 = 0;
+               for (i = 0; i < 8; i++) {
+                       if (likely(acpi_ec_read(0x78 + i, &t))) {
+                               ta1 |= t;
+                       } else {
+                               ta1 = 0;
+                               break;
+                       }
+                       if (likely(acpi_ec_read(0xC0 + i, &t))) {
+                               ta2 |= t;
+                       } else {
+                               ta1 = 0;
+                               break;
+                       }
+               }
+               if (ta1 == 0) {
+                       /* This is sheer paranoia, but we handle it anyway */
+                       if (acpi_tmp7) {
+                               printk(IBM_ERR
+                                      "ThinkPad ACPI EC access misbehaving, "
+                                      "falling back to ACPI TMPx access mode\n");
+                               thermal_read_mode = IBMACPI_THERMAL_ACPI_TMP07;
+                       } else {
+                               printk(IBM_ERR
+                                      "ThinkPad ACPI EC access misbehaving, "
+                                      "disabling thermal sensors access\n");
+                               thermal_read_mode = IBMACPI_THERMAL_NONE;
+                       }
+               } else {
+                       thermal_read_mode =
+                           (ta2 != 0) ?
+                           IBMACPI_THERMAL_TPEC_16 : IBMACPI_THERMAL_TPEC_8;
+               }
+       } else if (acpi_tmp7) {
                if (acpi_evalf(ec_handle, NULL, "UPDT", "qv")) {
                        /* 600e/x, 770e, 770x */
                        thermal_read_mode = IBMACPI_THERMAL_ACPI_UPDT;
@@ -1309,12 +1359,30 @@ static int thermal_init(void)
 static int thermal_get_sensors(struct ibm_thermal_sensors_struct *s)
 {
        int i, t;
+       s8 tmp;
        char tmpi[] = "TMPi";
 
        if (!s)
                return -EINVAL;
 
        switch (thermal_read_mode) {
+#if IBMACPI_MAX_THERMAL_SENSORS >= 16
+       case IBMACPI_THERMAL_TPEC_16:
+               for (i = 0; i < 8; i++) {
+                       if (!acpi_ec_read(0xC0 + i, &tmp))
+                               return -EIO;
+                       s->temp[i + 8] = tmp * 1000;
+               }
+               /* fallthrough */
+#endif
+       case IBMACPI_THERMAL_TPEC_8:
+               for (i = 0; i < 8; i++) {
+                       if (!acpi_ec_read(0x78 + i, &tmp))
+                               return -EIO;
+                       s->temp[i] = tmp * 1000;
+               }
+               return (thermal_read_mode == IBMACPI_THERMAL_TPEC_16) ? 16 : 8;
+
        case IBMACPI_THERMAL_ACPI_UPDT:
                if (!acpi_evalf(ec_handle, NULL, "UPDT", "v"))
                        return -EIO;
@@ -2052,6 +2120,24 @@ static void acpi_ibm_exit(void)
        remove_proc_entry(IBM_DIR, acpi_root_dir);
 }
 
+static int __init check_dmi_for_ec(void)
+{
+       struct dmi_device *dev = NULL;
+
+       /*
+        * ThinkPad T23 or newer, A31 or newer, R50e or newer,
+        * X32 or newer, all Z series;  Some models must have an
+        * up-to-date BIOS or they will not be detected.
+        *
+        * See http://thinkwiki.org/wiki/List_of_DMI_IDs
+        */
+       while ((dev = dmi_find_device(DMI_DEV_TYPE_OEM_STRING, NULL, dev))) {
+               if (strstr(dev->name, "IBM ThinkPad Embedded Controller"))
+                       return 1;
+       }
+       return 0;
+}
+
 static int __init acpi_ibm_init(void)
 {
        int ret, i;
@@ -2071,6 +2157,9 @@ static int __init acpi_ibm_init(void)
                return -ENODEV;
        }
 
+       /* Models with newer firmware report the EC in DMI */
+       ibm_thinkpad_ec_found = check_dmi_for_ec();
+
        /* these handles are not required */
        IBM_HANDLE_INIT(vid);
        IBM_HANDLE_INIT(vid2);