This patch causes TIPC to return an error indication if the non-
blocking form of connect() is requested (which TIPC does not yet
support).
Signed-off-by: Allan Stephens <allan.stephens@windriver.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
if (sock->state == SS_READY)
return -EOPNOTSUPP;
+ /* For now, TIPC does not support the non-blocking form of connect() */
+
+ if (flags & O_NONBLOCK)
+ return -EWOULDBLOCK;
+
/* Issue Posix-compliant error code if socket is in the wrong state */
if (sock->state == SS_LISTENING)