The IPMI specifcation says the generator ID is 0x20, but that is for bits
7-1. Bit 0 is set to specify it is a software event. The correct value is
0x41. Without this fix, panic events written into the System Event Log
appear to come from an "unknown" generator, rather than from the kernel.
Signed-off-by: Jordan Hargrave <Jordan_Hargrave@dell.com> Signed-off-by: Matt Domsch <Matt_Domsch@dell.com> Acked-by: Corey Minyard <minyard@acm.org> Signed-off-by: Andrew Morton <akpm@osdl.org> Signed-off-by: Linus Torvalds <torvalds@osdl.org>