[S390] permanent subchannel busy conditions may cause I/O stall
In special conditions where a subchannel rejects the HALT I/O-
instruction with a busy indication (cc 2), I/O may stall.
I/O request termination logic retries HALT I/O indefinitely
because it expects HALT I/O to alter the subchannel status which
is not true when cc 2 is returned.
In case of a busy indication, try CLEAR I/O instruction immediately.
Signed-off-by: Peter Oberparleiter <peter.oberparleiter@de.ibm.com> Signed-off-by: Martin Schwidefsky <schwidefsky@de.ibm.com>