X-Git-Url: https://err.no/cgi-bin/gitweb.cgi?a=blobdiff_plain;f=drivers%2Fpower%2Folpc_battery.c;h=32570af3c5c904fa86cffe26efbcc7650757d474;hb=04489eeb02a40bc15029886cef7285ada3ab0de6;hp=af7a231092a461052af4408f6e127901622e4f29;hpb=877c357e7511395bc923ec9efc2e8b021a17ed79;p=linux-2.6 diff --git a/drivers/power/olpc_battery.c b/drivers/power/olpc_battery.c index af7a231092..32570af3c5 100644 --- a/drivers/power/olpc_battery.c +++ b/drivers/power/olpc_battery.c @@ -19,7 +19,7 @@ #define EC_BAT_VOLTAGE 0x10 /* uint16_t, *9.76/32, mV */ #define EC_BAT_CURRENT 0x11 /* int16_t, *15.625/120, mA */ -#define EC_BAT_ACR 0x12 +#define EC_BAT_ACR 0x12 /* int16_t, *6250/15, µAh */ #define EC_BAT_TEMP 0x13 /* uint16_t, *100/256, °C */ #define EC_AMB_TEMP 0x14 /* uint16_t, *100/256, °C */ #define EC_BAT_STATUS 0x15 /* uint8_t, bitmask */ @@ -84,6 +84,119 @@ static struct power_supply olpc_ac = { .get_property = olpc_ac_get_prop, }; +static char bat_serial[17]; /* Ick */ + +static int olpc_bat_get_status(union power_supply_propval *val, uint8_t ec_byte) +{ + if (olpc_platform_info.ecver > 0x44) { + if (ec_byte & BAT_STAT_CHARGING) + val->intval = POWER_SUPPLY_STATUS_CHARGING; + else if (ec_byte & BAT_STAT_DISCHARGING) + val->intval = POWER_SUPPLY_STATUS_DISCHARGING; + else if (ec_byte & BAT_STAT_FULL) + val->intval = POWER_SUPPLY_STATUS_FULL; + else /* er,... */ + val->intval = POWER_SUPPLY_STATUS_NOT_CHARGING; + } else { + /* Older EC didn't report charge/discharge bits */ + if (!(ec_byte & BAT_STAT_AC)) /* No AC means discharging */ + val->intval = POWER_SUPPLY_STATUS_DISCHARGING; + else if (ec_byte & BAT_STAT_FULL) + val->intval = POWER_SUPPLY_STATUS_FULL; + else /* Not _necessarily_ true but EC doesn't tell all yet */ + val->intval = POWER_SUPPLY_STATUS_CHARGING; + } + + return 0; +} + +static int olpc_bat_get_health(union power_supply_propval *val) +{ + uint8_t ec_byte; + int ret; + + ret = olpc_ec_cmd(EC_BAT_ERRCODE, NULL, 0, &ec_byte, 1); + if (ret) + return ret; + + switch (ec_byte) { + case 0: + val->intval = POWER_SUPPLY_HEALTH_GOOD; + break; + + case BAT_ERR_OVERTEMP: + val->intval = POWER_SUPPLY_HEALTH_OVERHEAT; + break; + + case BAT_ERR_OVERVOLTAGE: + val->intval = POWER_SUPPLY_HEALTH_OVERVOLTAGE; + break; + + case BAT_ERR_INFOFAIL: + case BAT_ERR_OUT_OF_CONTROL: + case BAT_ERR_ID_FAIL: + case BAT_ERR_ACR_FAIL: + val->intval = POWER_SUPPLY_HEALTH_UNSPEC_FAILURE; + break; + + default: + /* Eep. We don't know this failure code */ + ret = -EIO; + } + + return ret; +} + +static int olpc_bat_get_mfr(union power_supply_propval *val) +{ + uint8_t ec_byte; + int ret; + + ec_byte = BAT_ADDR_MFR_TYPE; + ret = olpc_ec_cmd(EC_BAT_EEPROM, &ec_byte, 1, &ec_byte, 1); + if (ret) + return ret; + + switch (ec_byte >> 4) { + case 1: + val->strval = "Gold Peak"; + break; + case 2: + val->strval = "BYD"; + break; + default: + val->strval = "Unknown"; + break; + } + + return ret; +} + +static int olpc_bat_get_tech(union power_supply_propval *val) +{ + uint8_t ec_byte; + int ret; + + ec_byte = BAT_ADDR_MFR_TYPE; + ret = olpc_ec_cmd(EC_BAT_EEPROM, &ec_byte, 1, &ec_byte, 1); + if (ret) + return ret; + + switch (ec_byte & 0xf) { + case 1: + val->intval = POWER_SUPPLY_TECHNOLOGY_NiMH; + break; + case 2: + val->intval = POWER_SUPPLY_TECHNOLOGY_LiFe; + break; + default: + val->intval = POWER_SUPPLY_TECHNOLOGY_UNKNOWN; + break; + } + + return ret; +} + /********************************************************************* * Battery properties *********************************************************************/ @@ -94,6 +207,7 @@ static int olpc_bat_get_property(struct power_supply *psy, int ret = 0; int16_t ec_word; uint8_t ec_byte; + uint64_t ser_buf; ret = olpc_ec_cmd(EC_BAT_STATUS, NULL, 0, &ec_byte, 1); if (ret) @@ -110,25 +224,10 @@ static int olpc_bat_get_property(struct power_supply *psy, switch (psp) { case POWER_SUPPLY_PROP_STATUS: - if (olpc_platform_info.ecver > 0x44) { - if (ec_byte & BAT_STAT_CHARGING) - val->intval = POWER_SUPPLY_STATUS_CHARGING; - else if (ec_byte & BAT_STAT_DISCHARGING) - val->intval = POWER_SUPPLY_STATUS_DISCHARGING; - else if (ec_byte & BAT_STAT_FULL) - val->intval = POWER_SUPPLY_STATUS_FULL; - else /* er,... */ - val->intval = POWER_SUPPLY_STATUS_NOT_CHARGING; - } else { - /* Older EC didn't report charge/discharge bits */ - if (!(ec_byte & BAT_STAT_AC)) /* No AC means discharging */ - val->intval = POWER_SUPPLY_STATUS_DISCHARGING; - else if (ec_byte & BAT_STAT_FULL) - val->intval = POWER_SUPPLY_STATUS_FULL; - else /* Not _necessarily_ true but EC doesn't tell all yet */ - val->intval = POWER_SUPPLY_STATUS_CHARGING; - break; - } + ret = olpc_bat_get_status(val, ec_byte); + if (ret) + return ret; + break; case POWER_SUPPLY_PROP_PRESENT: val->intval = !!(ec_byte & BAT_STAT_PRESENT); break; @@ -137,72 +236,21 @@ static int olpc_bat_get_property(struct power_supply *psy, if (ec_byte & BAT_STAT_DESTROY) val->intval = POWER_SUPPLY_HEALTH_DEAD; else { - ret = olpc_ec_cmd(EC_BAT_ERRCODE, NULL, 0, &ec_byte, 1); + ret = olpc_bat_get_health(val); if (ret) return ret; - - switch (ec_byte) { - case 0: - val->intval = POWER_SUPPLY_HEALTH_GOOD; - break; - - case BAT_ERR_OVERTEMP: - val->intval = POWER_SUPPLY_HEALTH_OVERHEAT; - break; - - case BAT_ERR_OVERVOLTAGE: - val->intval = POWER_SUPPLY_HEALTH_OVERVOLTAGE; - break; - - case BAT_ERR_INFOFAIL: - case BAT_ERR_OUT_OF_CONTROL: - case BAT_ERR_ID_FAIL: - case BAT_ERR_ACR_FAIL: - val->intval = POWER_SUPPLY_HEALTH_UNSPEC_FAILURE; - break; - - default: - /* Eep. We don't know this failure code */ - return -EIO; - } } break; case POWER_SUPPLY_PROP_MANUFACTURER: - ec_byte = BAT_ADDR_MFR_TYPE; - ret = olpc_ec_cmd(EC_BAT_EEPROM, &ec_byte, 1, &ec_byte, 1); + ret = olpc_bat_get_mfr(val); if (ret) return ret; - - switch (ec_byte >> 4) { - case 1: - val->strval = "Gold Peak"; - break; - case 2: - val->strval = "BYD"; - break; - default: - val->strval = "Unknown"; - break; - } break; case POWER_SUPPLY_PROP_TECHNOLOGY: - ec_byte = BAT_ADDR_MFR_TYPE; - ret = olpc_ec_cmd(EC_BAT_EEPROM, &ec_byte, 1, &ec_byte, 1); + ret = olpc_bat_get_tech(val); if (ret) return ret; - - switch (ec_byte & 0xf) { - case 1: - val->intval = POWER_SUPPLY_TECHNOLOGY_NiMH; - break; - case 2: - val->intval = POWER_SUPPLY_TECHNOLOGY_LiFe; - break; - default: - val->intval = POWER_SUPPLY_TECHNOLOGY_UNKNOWN; - break; - } break; case POWER_SUPPLY_PROP_VOLTAGE_AVG: ret = olpc_ec_cmd(EC_BAT_VOLTAGE, NULL, 0, (void *)&ec_word, 2); @@ -241,6 +289,22 @@ static int olpc_bat_get_property(struct power_supply *psy, ec_word = be16_to_cpu(ec_word); val->intval = ec_word * 100 / 256; break; + case POWER_SUPPLY_PROP_CHARGE_COUNTER: + ret = olpc_ec_cmd(EC_BAT_ACR, NULL, 0, (void *)&ec_word, 2); + if (ret) + return ret; + + ec_word = be16_to_cpu(ec_word); + val->intval = ec_word * 6250 / 15; + break; + case POWER_SUPPLY_PROP_SERIAL_NUMBER: + ret = olpc_ec_cmd(EC_BAT_SERIAL, NULL, 0, (void *)&ser_buf, 8); + if (ret) + return ret; + + sprintf(bat_serial, "%016llx", (long long)be64_to_cpu(ser_buf)); + val->strval = bat_serial; + break; default: ret = -EINVAL; break; @@ -260,6 +324,50 @@ static enum power_supply_property olpc_bat_props[] = { POWER_SUPPLY_PROP_TEMP, POWER_SUPPLY_PROP_TEMP_AMBIENT, POWER_SUPPLY_PROP_MANUFACTURER, + POWER_SUPPLY_PROP_SERIAL_NUMBER, + POWER_SUPPLY_PROP_CHARGE_COUNTER, +}; + +/* EEPROM reading goes completely around the power_supply API, sadly */ + +#define EEPROM_START 0x20 +#define EEPROM_END 0x80 +#define EEPROM_SIZE (EEPROM_END - EEPROM_START) + +static ssize_t olpc_bat_eeprom_read(struct kobject *kobj, + struct bin_attribute *attr, char *buf, loff_t off, size_t count) +{ + uint8_t ec_byte; + int ret, end; + + if (off >= EEPROM_SIZE) + return 0; + if (off + count > EEPROM_SIZE) + count = EEPROM_SIZE - off; + + end = EEPROM_START + off + count; + for (ec_byte = EEPROM_START + off; ec_byte < end; ec_byte++) { + ret = olpc_ec_cmd(EC_BAT_EEPROM, &ec_byte, 1, + &buf[ec_byte - EEPROM_START], 1); + if (ret) { + printk(KERN_ERR "olpc-battery: EC command " + "EC_BAT_EEPROM @ 0x%x failed -" + " %d!\n", ec_byte, ret); + return -EIO; + } + } + + return count; +} + +static struct bin_attribute olpc_bat_eeprom = { + .attr = { + .name = "eeprom", + .mode = S_IRUGO, + .owner = THIS_MODULE, + }, + .size = 0, + .read = olpc_bat_eeprom_read, }; /********************************************************************* @@ -290,8 +398,14 @@ static int __init olpc_bat_init(void) if (!olpc_platform_info.ecver) return -ENXIO; - if (olpc_platform_info.ecver < 0x43) { - printk(KERN_NOTICE "OLPC EC version 0x%02x too old for battery driver.\n", olpc_platform_info.ecver); + + /* + * We've seen a number of EC protocol changes; this driver requires + * the latest EC protocol, supported by 0x44 and above. + */ + if (olpc_platform_info.ecver < 0x44) { + printk(KERN_NOTICE "OLPC EC version 0x%02x too old for " + "battery driver.\n", olpc_platform_info.ecver); return -ENXIO; } @@ -315,9 +429,14 @@ static int __init olpc_bat_init(void) if (ret) goto battery_failed; - olpc_register_battery_callback(&olpc_battery_trigger_uevent); + ret = device_create_bin_file(olpc_bat.dev, &olpc_bat_eeprom); + if (ret) + goto eeprom_failed; + goto success; +eeprom_failed: + power_supply_unregister(&olpc_bat); battery_failed: power_supply_unregister(&olpc_ac); ac_failed: @@ -328,7 +447,7 @@ success: static void __exit olpc_bat_exit(void) { - olpc_deregister_battery_callback(); + device_remove_bin_file(olpc_bat.dev, &olpc_bat_eeprom); power_supply_unregister(&olpc_bat); power_supply_unregister(&olpc_ac); platform_device_unregister(bat_pdev);