X-Git-Url: https://err.no/cgi-bin/gitweb.cgi?a=blobdiff_plain;f=Documentation%2Fpower%2Fpower_supply_class.txt;h=c6cd4956047c2f88c24ef5df0282193e885b6b3e;hb=13601cd8e44aab332cedff1d6dc10786ec890b7b;hp=a8686e5a68579fc207d4c12e59246d7aee58ffcd;hpb=53471121a8aad3f0b590bfce7c95a1f5f52150f3;p=linux-2.6 diff --git a/Documentation/power/power_supply_class.txt b/Documentation/power/power_supply_class.txt index a8686e5a68..c6cd495604 100644 --- a/Documentation/power/power_supply_class.txt +++ b/Documentation/power/power_supply_class.txt @@ -101,6 +101,10 @@ of charge when battery became full/empty". It also could mean "value of charge when battery considered full/empty at given conditions (temperature, age)". I.e. these attributes represents real thresholds, not design values. +CHARGE_COUNTER - the current charge counter (in µAh). This could easily +be negative; there is no empty or full value. It is only useful for +relative, time-based measurements. + ENERGY_FULL, ENERGY_EMPTY - same as above but for energy. CAPACITY - capacity in percents.