* Address is fully defined internally and cannot be changed.
*/
-static unsigned short normal_i2c[] = { 0x4c, I2C_CLIENT_END };
+static const unsigned short normal_i2c[] = { 0x4c, I2C_CLIENT_END };
/*
* Insmod parameters
/* Start converting if needed */
if (data->config & 0x40) { /* standby */
- dev_dbg(&client->dev, "Switching to operational mode");
+ dev_dbg(&client->dev, "Switching to operational mode\n");
data->config &= 0xA7;
i2c_smbus_write_byte_data(client, LM63_REG_CONFIG1,
data->config);