- * The Maxim variants do NOT have a chip_id register.
- * Reading from that address will return the last read
- * value, which in our case is those of the man_id
- * register. Likewise, the config1 register seems to
- * lack a low nibble, so the value will be those of the
- * previous read, so in our case those of the man_id
- * register.
+ * The MAX6657, MAX6658 and MAX6659 do NOT have a
+ * chip_id register. Reading from that address will
+ * return the last read value, which in our case is
+ * those of the man_id register. Likewise, the config1
+ * register seems to lack a low nibble, so the value
+ * will be those of the previous read, so in our case
+ * those of the man_id register.