-If the concurrent sense flag in the extended status word in the irb is set, the
-field irb->scsw.count describes the number of device specific sense bytes
-available in the extended control word irb->scsw.ecw[0]. No device sensing by
-the device driver itself is required.
+If the concurrent sense flag in the extended status word (esw) in the irb is
+set, the field erw.scnt in the esw describes the number of device specific
+sense bytes available in the extended control word irb->scsw.ecw[]. No device
+sensing by the device driver itself is required.